Avalon
Anti-Wear Hydraulic Oil
Hydraulic Oils
Avalon

Veedol Avalon is a range of superior quality anti-wear hydraulic oils that are meant for most industrial applications working under moderate operating conditions.
Formulated with proven anti-wear, rust and oxidation inhibitor technology, they provide very good protection to the hydraulic components while inhibiting rust and oxidation thus improving system performance.
Formulated with proven anti-wear, rust and oxidation inhibitor technology, they provide very good protection to the hydraulic components while inhibiting rust and oxidation thus improving system performance.
Features/Benefits:
- Very good resistance to oxidation helps filter blocking and valve sticking.
- Outstanding anti-wear protection helps extend hydraulic system component life and reduce maintenance cost.
- Good water and foaming resistance provide improved system efficiency.
- Excellent rust & corrosion protection prolongs component overhaul interval
Performance Specification:
Veedol Avalon meets & exceeds the performance requirements of
- IS: 10522-1983 (Reaffirmed 2004)
- DIN 51524 Part 1 HL
- Vickers V-104C Vane Pump Test
Application:
- Avalon 32 – 100 can be used in industrial hydraulic systems requiring mild anti-wear characteristics.
- Hydraulic systems with vane, gear, or piston pumps, hydraulic couplings.
- Avalon 150 and above are suitable for lubrication of gears and circulating systems where the manufacturer recommends such type of oils.
- Lubrication of machine tools, antifriction, and plain bearings.
- Mobile hydraulic equipment where this type of anti-wear hydraulic oil is recommended
Typical Properties:
| Parameters | Test Method | 32 | 46 | 68 | 100 |
|---|---|---|---|---|---|
| Density at 29.5ºC | ASTM D4052 | 0.850 | 0.854 | 0.870 | 0.882 |
| Kinematic Viscosity @ 40ºC, cSt | ASTM D445 | 32 | 46.66 | 68.5 | 98.9 |
| Kinematic Viscosity @ 100ºC, cSt | ASTM D445 | 5.35 | 6.88 | 8.74 | 1.03 |
| Viscosity Index | ASTM D2270 | 99 | 102 | 99 | 95 |
| Pour Point, ºC | ASTM D97 | -18 | -18 | -18 | -9 |
| Copper Corrosion at 100 ºC, 3 hours | ASTM D130 | 1a | 1a | 1a | 1a |
| Foaming Tendency/ Stability Sequence I, mL/mL Sequence II, mL/mL Sequence III, mL/mL |
ASTM D892 | 0/0 10/0 0/0 |
0/0 10/0 0/0 |
0/0 10/0 0/0 |
0/0 10/0 0/0 |
| Rust Test | ASTM D665 | Pass | Pass | Pass | Pass |
| FZG (A/8.3/90), Load stage | DIN 51354-2 | 10pass | 10pass | 10pass | 10pass |
| TOST Life, Time to 2.0 TAN, hours | ASTM D943 | >1500 | >1500 | >1500 | >1500 |
| Parameters | Test Method | 150 | 220 | 320 | 460 |
|---|---|---|---|---|---|
| Density at 29.5ºC | ASTM D4052 | 0.884 | 0.890 | 0.894 | 0.897 |
| Kinematic Viscosity @ 40ºC, cSt | ASTM D445 | 151.5 | 222.4 | 321.1 | 98.9 |
| Kinematic Viscosity @ 100ºC, cSt | ASTM D445 | 14.65 | 18.90 | 24.10 | 30.51 |
| Viscosity Index | ASTM D2270 | 95 | 95 | 95 | 95 |
| Pour Point, ºC | ASTM D97 | -9 | -6 | -6 | -6 |
| Copper Corrosion at 100 ºC, 3 hours | ASTM D130 | 1a | 1a | 1a | 1a |
| Foaming Tendency/ Stability Sequence I, mL/mL Sequence II, mL/mL Sequence III, mL/mL |
ASTM D892 | 0/0 10/0 0/0 |
0/0 10/0 0/0 |
0/0 10/0 0/0 |
0/0 10/0 0/0 |
| Rust Test | ASTM D665 | Pass | Pass | Pass | Pass |
| FZG (A/8.3/90), Load stage | DIN 51354-2 | 10pass | – | – | – |
| TOST Life, Time to 2.0 TAN, hours | ASTM D943 | >1000 | – | – | – |
The above typical properties are those obtained with normal production tolerance and do not constitute a specification. Variations that do not affect product performance are to be expected during normal manufacture and at different blending locations. The information contained herein is subject to change without notice.
Storage:
All packages should be stored under cover. It should not be exposed to direct sunlight, intense cold and extreme temperature fluctuations. Where outside storage is unavoidable, drums should be laid horizontally or properly covered to avoid the possible ingress of water and damage to drum markings.
Health and Safety:
The information on this product is available in the Material Safety Data Sheet (MSDS) as a guide to the precautions and safe handling of this product and its disposal. For further information, we recommend you review the MSDS. If handled correctly, there are no special precautions suggested.