Avalon HLP
Heavy Duty Hydraulic Oil
Hydraulic Oils
Avalon HLP

Blended with severely hydro-processed base oils and advanced additive system, they provide enhanced protection to hydraulic components compared to conventional hydraulic oil. Avalon HLP series hydraulic oils have passed the stringent Bosch Rexroth RFT-APU-CL pump test.
Features/Benefits:
- Enhanced anti-wear and corrosion protection help extend component life and improve equipment output.
- Excellent oxidation stability helps in maintaining system cleanliness and deposit reduction, enable long oil and filter life thus reduce downtime and operating costs.
- Outstanding filterability, faster air release and water separation contribute to enhance and maintain efficiency of hydraulic system.
Performance Specification:
- DIN 51524-2, HLP
- Parker HF-0, HF-1, HF-2
- Bosch Rexroth RD 90220
- Eaton E-FDGN-TB002-E specification, Eaton M-2950-S & I-286-S3
- Fives Cincinnati P-68, P-70, P-69
- IS: 11656-1986 (Reaffirmed 1991), IS: 10522-1983 (Reaffirmed 2004)
- ASTM D 6158
Application:
- High pressure hydraulic systems found in various manufacturing industries.
- Construction and mining equipment where HLP type hydraulic oils are recommended.
- Hydraulic applications requiring extended oil drain interval.
- Recommended for hydraulic systems subjected to high pressure and load
Approvals:
- Bosch Rexroth RD 90220 (Fluid Rating List RDE 90245)
- Voith Turbo Variable speed coupling Type “S”, Torque converter Type “E” and Geared Variable speed coupling type “R” (Avalon HLP32)
- Injection Molding Machine manufacturer: Milacron, Windsor Machines Ltd
Typical Properties:
| Parameters | Test Method | 32 | 46 | 68 |
|---|---|---|---|---|
| Density at 29.5ºC | ASTM D4052 | 0.843 | 0.845 | 0.850 |
| Kinematic Viscosity @ 40ºC, cSt | ASTM D445 | 32.5 | 46.0 | 68.03 |
| Kinematic Viscosity @ 100ºC, cSt | ASTM D445 | 5.58 | 7.02 | 8.97 |
| Viscosity Index | ASTM D2270 | 109 | 110 | 105 |
| Flash Point (COC), ºC | ASTM D92 | 220 | 232 | 236 |
| Pour Point, ºC | ASTM D97 | -9 | -9 | -9 |
| Copper Corrosion at 100 ºC, 3 hours | ASTM D130 | 1a | 1a | 1a |
| Foaming Tendency/ Stability Sequence I, mL/mL Sequence II, mL/mL Sequence III, mL/mL |
ASTM D892 | 0/0 10/0 0/0 |
0/0 10/0 0/0 |
0/0 10/0 0/0 |
| Air release at 50ºC, minutes | ASTM D3427 | 2’18” | 3’51” | 5’42” |
| Rust Test | ASTM D665 | Pass | Pass | Pass |
| TOST Life, hours | ASTM D943 | >4500 | >4500 | >4600 |
| FZG Fail load stage (A/8.3/90) | DIN 51354-2 | 11 | 11 | 12 |
The above typical properties are those obtained with normal production tolerance and do not constitute a specification. Variations that do not affect product performance are to be expected during normal manufacture and at different
blending locations. The information contained herein is subject to change without notice
Storage:
All packages should be stored under cover. It should not be exposed to direct sunlight, intense cold and extreme temperature fluctuations. Where outside storage is unavoidable, drums should be laid horizontally or properly covered to avoid the possible ingress of water and damage to drum markings.